Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 133
Filtrar
1.
Expert Rev Med Devices ; : 1-14, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38618982

RESUMO

INTRODUCTION: The identification of early-stage colorectal cancers (CRC) and the resection of pre-cancerous neoplastic lesions through colonoscopy allows to decrease both CRC incidence and mortality. However, colonoscopy miss rates up to 26% for adenomas and 9% for advanced adenomas have been reported. In recent years, artificial intelligence (AI) systems have been emerging as easy-to-use tools, potentially lowering the risk of missing lesions. AREAS COVERED: This review paper focuses on GI Genius device (Medtronic Co. Minneapolis, MN, U.S.A.) a computer-assisted tool designed to assist endoscopists during standard white-light colonoscopies in detecting mucosal lesions. EXPERT OPINION: Randomized controlled trials (RCTs) suggest that GI Genius is a safe and effective tool for improving adenoma detection, especially in CRC screening and surveillance colonoscopies. However, its impact seems to be less significant among experienced endoscopists and in real-world clinical scenarios compared to the controlled conditions of RCTs. Furthermore, it appears that GI Genius mainly enhances the detection of non-advanced, small polyps, but does not significantly impact the identification of advanced and difficult-to-detect adenoma. When using GI Genius, no complications were documented. Only a small number of studies reported an increased in withdrawal time or the removal of non-neoplastic lesions.

4.
Gastrointest Endosc ; 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38272273

RESUMO

BACKGROUND AND AIMS: Small bowel (SB) capsule endoscopy (CE) is a first line procedure for exploring the SB. Endoscopic GastroIntestinal PlacemenT (EGIPT) of SB CE is sometimes necessary. While the experience of EGIPT is large in pediatric populations, we aimed to describe the safety, efficacy and outcomes of EGIPT of SB CE in adult patients. METHODS: The international CApsule endoscopy REsearch (iCARE) group set up a retrospective multicenter study. Patients over 18 year-old who underwent EGIPT of SB CE before May 2022 were included. Data were collected from medical records and capsule recordings. The primary endpoint was the technical success rate of the EGIPT procedures. RESULTS: 630 patients were included (mean age 62.5 years old, 55.9% female) from 39,565 patients (1.6%) issued from 29 centers. EGIPT technical success was achieved in 610 procedures (96.8%). Anesthesia (moderate/deep sedation or general anesthesia) and centers with intermediate or high procedure loads were independent factors of technical success. Severe adverse events occurred in three (0.5%) patients. When technically successful, EGIPT was associated with a high SB CE completion rate (84.4%) and with a substantial diagnostic yield (61.1%). Completion rate was significantly higher when the capsule was delivered in the SB compared to when delivered in the stomach. CONCLUSION: EGIPT of SB CE is highly feasible, safe and comes with high completion rate and diagnostic yield. When indicated, it should rather be performed under anesthesia and the capsule should be delivered in the duodenum rather than in the stomach, for better SB examination outcomes.

6.
Best Pract Res Clin Gastroenterol ; 67: 101871, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38103927

RESUMO

Several scoring systems have been developed for both upper and lower GI bleeding to predict the bleeding severity and discriminate between low-risk patients, who may be suitable for outpatient management, and those who would likely need hospital-based interventions and are at high risk for adverse outcomes. Risk scores created to identify low-risk patients (namely the Glasgow Blatchford Score and the Oakland score) showed very good discriminative performances and their implementation has proven to be effective in reducing hospital admissions and healthcare burden. Conversely, the performances of risk scores in identifying specific adverse events to define high-risk patients are less accurate, and whether their integration into routine clinical practice has a tangible impact on patient management remains unproven. This review describes the existing risk score systems for GI bleeding, emphasizes key research findings, elucidates the circumstances in which their utilization can be beneficial, examines their constraints when considering routine clinical application, and discuss future development.


Assuntos
Hemorragia Gastrointestinal , Hospitais , Humanos , Medição de Risco , Índice de Gravidade de Doença , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Fatores de Risco , Prognóstico , Estudos Retrospectivos
9.
Ann Intern Med ; 176(9): 1209-1220, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37639719

RESUMO

BACKGROUND: Artificial intelligence computer-aided detection (CADe) of colorectal neoplasia during colonoscopy may increase adenoma detection rates (ADRs) and reduce adenoma miss rates, but it may increase overdiagnosis and overtreatment of nonneoplastic polyps. PURPOSE: To quantify the benefits and harms of CADe in randomized trials. DESIGN: Systematic review and meta-analysis. (PROSPERO: CRD42022293181). DATA SOURCES: Medline, Embase, and Scopus databases through February 2023. STUDY SELECTION: Randomized trials comparing CADe-assisted with standard colonoscopy for polyp and cancer detection. DATA EXTRACTION: Adenoma detection rate (proportion of patients with ≥1 adenoma), number of adenomas detected per colonoscopy, advanced adenoma (≥10 mm with high-grade dysplasia and villous histology), number of serrated lesions per colonoscopy, and adenoma miss rate were extracted as benefit outcomes. Number of polypectomies for nonneoplastic lesions and withdrawal time were extracted as harm outcomes. For each outcome, studies were pooled using a random-effects model. Certainty of evidence was assessed using the GRADE (Grading of Recommendations Assessment, Development and Evaluation) framework. DATA SYNTHESIS: Twenty-one randomized trials on 18 232 patients were included. The ADR was higher in the CADe group than in the standard colonoscopy group (44.0% vs. 35.9%; relative risk, 1.24 [95% CI, 1.16 to 1.33]; low-certainty evidence), corresponding to a 55% (risk ratio, 0.45 [CI, 0.35 to 0.58]) relative reduction in miss rate (moderate-certainty evidence). More nonneoplastic polyps were removed in the CADe than the standard group (0.52 vs. 0.34 per colonoscopy; mean difference [MD], 0.18 polypectomy [CI, 0.11 to 0.26 polypectomy]; low-certainty evidence). Mean inspection time increased only marginally with CADe (MD, 0.47 minute [CI, 0.23 to 0.72 minute]; moderate-certainty evidence). LIMITATIONS: This review focused on surrogates of patient-important outcomes. Most patients, however, may consider cancer incidence and cancer-related mortality important outcomes. The effect of CADe on such patient-important outcomes remains unclear. CONCLUSION: The use of CADe for polyp detection during colonoscopy results in increased detection of adenomas but not advanced adenomas and in higher rates of unnecessary removal of nonneoplastic polyps. PRIMARY FUNDING SOURCE: European Commission Horizon 2020 Marie Sklodowska-Curie Individual Fellowship.


Assuntos
Inteligência Artificial , Neoplasias Colorretais , Humanos , Neoplasias Colorretais/diagnóstico , Computadores , Colonoscopia , Bases de Dados Factuais
10.
Dig Liver Dis ; 55(12): 1719-1724, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37394371

RESUMO

INTRODUCTION: The investigation of small bowel (SB) intussusception is variable, reflecting the lack of existing standards. The aim of this study was to understand the role of small bowel capsule endoscopy (SBCE) to investigate this pathology. METHODOLOGY: This was a retrospective multi-centre study. Patients with intussusception on SBCE and those where SBCE was carried out due to findings of intussusception on radiological investigations were included. Relevant information was collected. RESULTS: Ninety-five patients (median age 39+/-SD19.1 years, IQR 30) were included. Radiological investigations were carried out in 71 patients (74.7%) prior to SBCE with intussusception being present in 60 patients on radiological investigations (84.5%). Thirty patients (42.2%) had intussusception on radiological investigations followed by a normal SBCE. Ten patients (14.1%) had findings of intussusception on radiological investigations, a normal SBCE and repeat radiological investigations that were also normal. Abnormal findings were noted on SBCE that could explain intussusception on imaging in (16 patients) 22.5% of patients. Five patients (5.3%) underwent radiological investigations and SBCE to investigate coeliac disease and intussusception. None had associated malignancy. Four patients (4.2%) underwent SBCE to investigate familial polyposis syndromes and went on to SB enteroscopy and surgery accordingly. Most patients (n = 14; 14.8%) with intussusception on initial SBCE (without prior radiological imaging) had suspected SB bleeding (n = 10, 10.5%). Four patients (4.2%) had additional findings of a mass on CT scan and went on to have surgery. CONCLUSION: SBCE should be used to complement radiology when investigating intussusception. It is a safe non-invasive test that will minimise unnecessary surgery. Additional radiological investigations following a negative SBCE in cases of intussusception noted on initial radiological investigations are unlikely to yield positive findings. Radiological investigations following intussusception noted on SBCE in case of patients presenting with obscure gastrointestinal bleeding, may yield additional findings.


Assuntos
Endoscopia por Cápsula , Doença Celíaca , Intussuscepção , Adulto , Humanos , Algoritmos , Endoscopia por Cápsula/métodos , Doença Celíaca/patologia , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/etiologia , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Intussuscepção/diagnóstico por imagem , Estudos Retrospectivos
11.
Gastroenterology ; 165(1): 244-251.e3, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37061169

RESUMO

BACKGROUND & AIMS: Both computer-aided detection (CADe)-assisted and Endocuff-assisted colonoscopy have been found to increase adenoma detection. We investigated the performance of the combination of the 2 tools compared with CADe-assisted colonoscopy alone to detect colorectal neoplasias during colonoscopy in a multicenter randomized trial. METHODS: Men and women undergoing colonoscopy for colorectal cancer screening, polyp surveillance, or clincial indications at 6 centers in Italy and Switzerland were enrolled. Patients were assigned (1:1) to colonoscopy with the combinations of CADe (GI-Genius; Medtronic) and a mucosal exposure device (Endocuff Vision [ECV]; Olympus) or to CADe-assisted colonoscopy alone (control group). All detected lesions were removed and sent to histopathology for diagnosis. The primary outcome was adenoma detection rate (percentage of patients with at least 1 histologically proven adenoma or carcinoma). Secondary outcomes were adenomas detected per colonoscopy, advanced adenomas and serrated lesions detection rate, the rate of unnecessary polypectomies (polyp resection without histologically proven adenomas), and withdrawal time. RESULTS: From July 1, 2021 to May 31, 2022, there were 1316 subjects randomized and eligible for analysis; 660 to the ECV group, 656 to the control group). The adenoma detection rate was significantly higher in the ECV group (49.6%) than in the control group (44.0%) (relative risk, 1.12; 95% CI, 1.00-1.26; P = .04). Adenomas detected per colonoscopy were significantly higher in the ECV group (mean ± SD, 0.94 ± 0.54) than in the control group (0.74 ± 0.21) (incidence rate ratio, 1.26; 95% CI, 1.04-1.54; P = .02). The 2 groups did not differ in term of detection of advanced adenomas and serrated lesions. There was no significant difference between groups in mean ± SD withdrawal time (9.01 ± 2.48 seconds for the ECV group vs 8.96 ± 2.24 seconds for controls; P = .69) or proportion of subjects undergoing unnecessary polypectomies (relative risk, 0.89; 95% CI, 0.69-1.14; P = .38). CONCLUSIONS: The combination of CADe and ECV during colonoscopy increases adenoma detection rate and adenomas detected per colonoscopy without increasing withdrawal time compared with CADe alone. CLINICALTRIALS: gov, Number: NCT04676308.


Assuntos
Adenoma , Neoplasias Colorretais , Masculino , Humanos , Feminino , Colonoscopia , Adenoma/diagnóstico por imagem , Adenoma/patologia , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Mucosa , Computadores
12.
Dig Liver Dis ; 55(1): 29-39, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36100515

RESUMO

BACKGROUND: Enteroscopy plays an important role in the management of small bowel bleeding. However, current guidelines are not specifically designed for small bowel bleeding and recommendations from different international societies do not always align. Consequently, there is heterogeneity in the definitions of clinical entities, clinical practice policies, and adherence to guidelines among clinicians. This represents an obstacle to providing the best patient care and to obtain homogeneous data for clinical research. AIMS: The aims of the study were to establish a consensus on the definitions of bleeding entities and on the role of enteroscopy in the management of small bowel bleeding using a Delphi process. METHODS: A core group of eight experts in enteroscopy identified five main topics of small bowel bleeding management and drafted statements on each topic. An expert panel of nine gastroenterologists participated in three rounds of the Delphi process, together with the core group. RESULTS: A total of 33 statements were approved after three rounds of Delphi voting. CONCLUSION: This Delphi consensus proposes clear definitions and a unifying strategy to standardize the management of small bowel bleeding. Furthermore, it provides a useful guide in daily practice for both clinical and technical issues of enteroscopy.


Assuntos
Endoscopia Gastrointestinal , Hemorragia Gastrointestinal , Humanos , Consenso , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/terapia , Técnica Delfos
13.
Endoscopy ; 55(1): 14-22, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35562098

RESUMO

BACKGROUND: Optical diagnosis of colonic polyps is poorly reproducible outside of high volume referral centers. The present study aimed to assess whether real-time artificial intelligence (AI)-assisted optical diagnosis is accurate enough to implement the leave-in-situ strategy for diminutive (≤ 5 mm) rectosigmoid polyps (DRSPs). METHODS: Consecutive colonoscopy outpatients with ≥ 1 DRSP were included. DRSPs were categorized as adenomas or nonadenomas by the endoscopists, who had differing expertise in optical diagnosis, with the assistance of a real-time AI system (CAD-EYE). The primary end point was ≥ 90 % negative predictive value (NPV) for adenomatous histology in high confidence AI-assisted optical diagnosis of DRSPs (Preservation and Incorporation of Valuable endoscopic Innovations [PIVI-1] threshold), with histopathology as the reference standard. The agreement between optical- and histology-based post-polypectomy surveillance intervals (≥ 90 %; PIVI-2 threshold) was also calculated according to European Society of Gastrointestinal Endoscopy (ESGE) and United States Multi-Society Task Force (USMSTF) guidelines. RESULTS: Overall 596 DRSPs were retrieved for histology in 389 patients; an AI-assisted high confidence optical diagnosis was made in 92.3 %. The NPV of AI-assisted optical diagnosis for DRSPs (PIVI-1) was 91.0 % (95 %CI 87.1 %-93.9 %). The PIVI-2 threshold was met with 97.4 % (95 %CI 95.7 %-98.9 %) and 92.6 % (95 %CI 90.0 %-95.2 %) of patients according to ESGE and USMSTF, respectively. AI-assisted optical diagnosis accuracy was significantly lower for nonexperts (82.3 %, 95 %CI 76.4 %-87.3 %) than for experts (91.9 %, 95 %CI 88.5 %-94.5 %); however, nonexperts quickly approached the performance levels of experts over time. CONCLUSION: AI-assisted optical diagnosis matches the required PIVI thresholds. This does not however offset the need for endoscopists' high level confidence and expertise. The AI system seems to be useful, especially for nonexperts.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Humanos , Inteligência Artificial , Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/cirurgia , Colonoscopia , Colo/patologia , Adenoma/diagnóstico por imagem , Adenoma/cirurgia , Imagem de Banda Estreita , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/cirurgia
14.
Gastrointest Endosc ; 97(5): 917-926.e3, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36572128

RESUMO

BACKGROUND AND AIMS: Meckel's diverticulum (MD) may remain silent or be associated with adverse events such as GI bleeding. The main aim of this study was to evaluate indicative small-bowel capsule endoscopy (SBCE) findings, and the secondary aim was to describe clinical presentation in patients with MD. METHODS: This retrospective European multicenter study included patients with MD undergoing SBCE from 2001 until July 2021. RESULTS: Sixty-nine patients with a confirmed MD were included. Median age was 32 years with a male-to-female ratio of approximately 3:1. GI bleeding or iron-deficiency anemia was present in nearly all patients. Mean hemoglobin was 7.63 ± 1.8 g/dL with a transfusion requirement of 52.2%. Typical capsule endoscopy (CE) findings were double lumen (n = 49 [71%]), visible entrance into the MD (n = 49 [71%]), mucosal webs (n = 30 [43.5%]), and bulges (n = 19 [27.5%]). Two or more of these findings were seen in 48 patients (69.6%). Ulcers were detected in 52.2% of patients (n = 36). In 63.8% of patients (n = 44), a combination of double lumen and visible entrance into the MD was evident, additionally revealing ulcers in 39.1% (n = 27). Mean percent SB (small bowel) transit time for the first indicative image of MD was 57% of the total SB transit time. CONCLUSIONS: Diagnosis of MD is rare and sometimes challenging, and a preoperative criterion standard does not exist. In SBCE, the most frequent findings were double-lumen sign and visible diverticular entrance, sometimes together with ulcers.


Assuntos
Endoscopia por Cápsula , Divertículo Ileal , Humanos , Masculino , Feminino , Adulto , Divertículo Ileal/diagnóstico , Divertículo Ileal/diagnóstico por imagem , Endoscopia por Cápsula/métodos , Estudos Retrospectivos , Úlcera/complicações , Abdome , Hemorragia Gastrointestinal/diagnóstico
15.
Eur J Gastroenterol Hepatol ; 35(2): 159-166, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36574306

RESUMO

INTRODUCTION: Bowel preparation is crucial for colonoscopy completeness and lesions detection. Today, several cleansing products are equally recommended by guidelines, irrespective of patients' characteristics. Identification of preparation-specific risk factors for inadequate bowel preparation may lead to a personalized prescription of cleansing products to refine patients' tolerance and improve endoscopic outcomes. METHODS: We prospectively enrolled consecutive outpatients referred for colonoscopy using either a high-volume [HV: 4 l polyethylene glycol (PEG)] or a low-volume (LV: 2 l PEG + bisacodyl) preparation. Day-before regimen or split-dose regimen was used for morning or afternoon colonoscopies, respectively. Univariate and multivariate analyses were conducted to identify risk factors related to inadequate bowel preparation, according to the Boston bowel preparation scale for HV and LV preparations. RESULTS: We enrolled 2040 patients, of which 1815 were included in the final analysis (average age 60.6 years, 50.2% men). Half of them (52%) used LV preparation. Adequate preparation was achieved by 87.6% without differences between the HV and LV groups (89.2% vs. 86.6%; P = 0.098). The use of day-before regimen and incomplete assumption of PEG were independent predictors of poor visibility for either HV or LV preparation. However, different specific risk factors for HV [diabetes: odds ratio (OR), 3.81; 95% confidence interval (CI), 1.91-7.58; low level of instruction: OR, 1.95; 95% CI, 1.11-3.44; and previous abdominal surgery: OR, 2.27; 95% CI, 1.20-4.30] and for LV (heart disease: OR, 2.06; 95% CI, 1.09-3.88; age > 65 years: OR, 1.51; 95% CI, 1.01-2.27) preparations were identified. CONCLUSION: Day-before preparation and incomplete assumption of the purgative agents affect bowel visibility irrespective of the preparation volume. LV should be preferred to HV preparations in patients with diabetes, low level of instruction, and previous abdominal surgery, whereas an HV preparation should be preferred in patients with heart disease and in older patients.


Assuntos
Catárticos , Diabetes Mellitus , Masculino , Humanos , Idoso , Pessoa de Meia-Idade , Feminino , Catárticos/efeitos adversos , Bisacodil/efeitos adversos , Polietilenoglicóis/efeitos adversos , Colonoscopia/efeitos adversos , Fatores de Risco
16.
Endoscopy ; 55(1): 58-95, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36423618

RESUMO

MR1: ESGE recommends small-bowel capsule endoscopy as the first-line examination, before consideration of other endoscopic and radiological diagnostic tests for suspected small-bowel bleeding, given the excellent safety profile of capsule endoscopy, its patient tolerability, and its potential to visualize the entire small-bowel mucosa.Strong recommendation, moderate quality evidence. MR2: ESGE recommends small-bowel capsule endoscopy in patients with overt suspected small-bowel bleeding as soon as possible after the bleeding episode, ideally within 48 hours, to maximize the diagnostic and subsequent therapeutic yield.Strong recommendation, high quality evidence. MR3: ESGE does not recommend routine second-look endoscopy prior to small-bowel capsule endoscopy in patients with suspected small-bowel bleeding or iron-deficiency anemia.Strong recommendation, low quality evidence. MR4: ESGE recommends conservative management in those patients with suspected small-bowel bleeding and high quality negative small-bowel capsule endoscopy.Strong recommendation, moderate quality evidence. MR5: ESGE recommends device-assisted enteroscopy to confirm and possibly treat lesions identified by small-bowel capsule endoscopy.Strong recommendation, high quality evidence. MR6: ESGE recommends the performance of small-bowel capsule endoscopy as a first-line examination in patients with iron-deficiency anemia when small bowel evaluation is indicated.Strong recommendation, high quality evidence. MR7: ESGE recommends small-bowel capsule endoscopy in patients with suspected Crohn's disease and negative ileocolonoscopy findings as the initial diagnostic modality for investigating the small bowel, in the absence of obstructive symptoms or known bowel stenosis.Strong recommendation, high quality evidence. MR8: ESGE recommends, in patients with unremarkable or nondiagnostic findings from dedicated small-bowel cross-sectional imaging, small-bowel capsule endoscopy as a subsequent investigation if deemed likely to influence patient management.Strong recommendation, low quality evidence. MR9: ESGE recommends, in patients with established Crohn's disease, the use of a patency capsule before small-bowel capsule endoscopy to decrease the capsule retention rate.Strong recommendation, moderate quality evidence. MR10: ESGE recommends device-assisted enteroscopy (DAE) as an alternative to surgery for foreign bodies retained in the small bowel requiring retrieval in patients without acute intestinal obstruction.Strong recommendation, moderate quality evidence. MR11: ESGE recommends DAE-endoscopic retrograde cholangiopancreatography (DAE-ERCP) as a first-line endoscopic approach to treat pancreaticobiliary diseases in patients with surgically altered anatomy (except for Billroth II patients).Strong recommendation, moderate quality evidence.


Assuntos
Anemia Ferropriva , Endoscopia por Cápsula , Doença de Crohn , Enteropatias , Humanos , Anemia Ferropriva/diagnóstico , Anemia Ferropriva/etiologia , Anemia Ferropriva/terapia , Endoscopia Gastrointestinal/métodos , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Enteropatias/diagnóstico , Enteropatias/terapia
17.
Diagnostics (Basel) ; 12(10)2022 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-36292089

RESUMO

Video-capsule endoscopy (VCE) reading is a time- and energy-consuming task. Agreement on findings between readers (either different or the same) is a crucial point for increasing performance and providing valid reports. The aim of this systematic review with meta-analysis is to provide an evaluation of inter/intra-observer agreement in VCE reading. A systematic literature search in PubMed, Embase and Web of Science was performed throughout September 2022. The degree of observer agreement, expressed with different test statistics, was extracted. As different statistics are not directly comparable, our analyses were stratified by type of test statistics, dividing them in groups of "None/Poor/Minimal", "Moderate/Weak/Fair", "Good/Excellent/Strong" and "Perfect/Almost perfect" to report the proportions of each. In total, 60 studies were included in the analysis, with a total of 579 comparisons. The quality of included studies, assessed with the MINORS score, was sufficient in 52/60 studies. The most common test statistics were the Kappa statistics for categorical outcomes (424 comparisons) and the intra-class correlation coefficient (ICC) for continuous outcomes (73 comparisons). In the overall comparison of inter-observer agreement, only 23% were evaluated as "good" or "perfect"; for intra-observer agreement, this was the case in 36%. Sources of heterogeneity (high, I2 81.8-98.1%) were investigated with meta-regressions, showing a possible role of country, capsule type and year of publication in Kappa inter-observer agreement. VCE reading suffers from substantial heterogeneity and sub-optimal agreement in both inter- and intra-observer evaluation. Artificial-intelligence-based tools and the adoption of a unified terminology may progressively enhance levels of agreement in VCE reading.

18.
Endoscopy ; 54(12): 1211-1231, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36270318

RESUMO

This ESGE Position Statement defines the expected value of artificial intelligence (AI) for the diagnosis and management of gastrointestinal neoplasia within the framework of the performance measures already defined by ESGE. This is based on the clinical relevance of the expected task and the preliminary evidence regarding artificial intelligence in artificial or clinical settings. MAIN RECOMMENDATIONS:: (1) For acceptance of AI in assessment of completeness of upper GI endoscopy, the adequate level of mucosal inspection with AI should be comparable to that assessed by experienced endoscopists. (2) For acceptance of AI in assessment of completeness of upper GI endoscopy, automated recognition and photodocumentation of relevant anatomical landmarks should be obtained in ≥90% of the procedures. (3) For acceptance of AI in the detection of Barrett's high grade intraepithelial neoplasia or cancer, the AI-assisted detection rate for suspicious lesions for targeted biopsies should be comparable to that of experienced endoscopists with or without advanced imaging techniques. (4) For acceptance of AI in the management of Barrett's neoplasia, AI-assisted selection of lesions amenable to endoscopic resection should be comparable to that of experienced endoscopists. (5) For acceptance of AI in the diagnosis of gastric precancerous conditions, AI-assisted diagnosis of atrophy and intestinal metaplasia should be comparable to that provided by the established biopsy protocol, including the estimation of extent, and consequent allocation to the correct endoscopic surveillance interval. (6) For acceptance of artificial intelligence for automated lesion detection in small-bowel capsule endoscopy (SBCE), the performance of AI-assisted reading should be comparable to that of experienced endoscopists for lesion detection, without increasing but possibly reducing the reading time of the operator. (7) For acceptance of AI in the detection of colorectal polyps, the AI-assisted adenoma detection rate should be comparable to that of experienced endoscopists. (8) For acceptance of AI optical diagnosis (computer-aided diagnosis [CADx]) of diminutive polyps (≤5 mm), AI-assisted characterization should match performance standards for implementing resect-and-discard and diagnose-and-leave strategies. (9) For acceptance of AI in the management of polyps ≥ 6 mm, AI-assisted characterization should be comparable to that of experienced endoscopists in selecting lesions amenable to endoscopic resection.


Assuntos
Endoscopia por Cápsula , Gastroenteropatias , Lesões Pré-Cancerosas , Humanos , Inteligência Artificial , Endoscopia Gastrointestinal/métodos , Endoscopia do Sistema Digestório , Endoscopia
19.
Dig Liver Dis ; 54(10): 1403-1409, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35934647

RESUMO

AIMS: The primary aim of this study was to assess the reliability, intra- and inter-observer variation of the SPICE, Mucosal protrusion angle (MPA) and SHYUNG scores in differentiating a subepithelial mass (SEM) from a bulge. METHODS: This retrospective multicentre study analysed the 3 scores, radiological studies, enteroscopy and/or surgical findings. RESULTS: 100 patients with a potential SEM (mean age 57.6years) were recruited with 75 patients having pathology. In patients with a SEM the mean SPICE score was 2.04 (95% CI 1.82-2.26) as compared to 1.16 (95% CI 0.81-1.51) without any pathology (AUC 0.74, p<0.001), with a fair intra-observer agreement (Kappa 0.3, p<0.001) and slight inter-observer agreement (Kappa 0.14, p<0.05). SPICE had a 37.3% sensitivity and 92.0% specificity in distinguishing between a SEM and bulge, whereas MPA<90˚ had 58.7% and 76.0% respectively, with poor intra-observer(p = 0.05) and interobserver agreement (p = 0.64). The SHYUNG demonstrated a moderate intra-observer (Kappa 0.44, p<0.001) and slight inter-observer reliability (Kappa 0.18, p<0.001). The sensitivity of an elevated SHYUNG score (≥4) in identifying a SEM was 18.7% with a specificity of 92.0% (AUC 0.71, p = 0.002). CONCLUSIONS: Though these scores are easy to use, they have, at best, slight to moderate intra and inter-observer agreement. Their overall diagnostic performances are limited.


Assuntos
Reprodutibilidade dos Testes , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Retrospectivos
20.
Clin Endosc ; 55(4): 473-479, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35831981

RESUMO

Over the last few years, capsule endoscopy has been established as a fundamental device in the practicing gastroenterologist's toolbox. Its utilization in diagnostic algorithms for suspected small bowel bleeding, Crohn's disease, and small bowel tumors has been approved by several guidelines. The advent of double-balloon enteroscopy has significantly increased the therapeutic possibilities and release of multiple devices (single-balloon enteroscopy and spiral enteroscopy) aimed at improving the performance of small bowel enteroscopy. Recently, some important innovations have appeared in the small bowel endoscopy scene, providing further improvement to its evolution. Artificial intelligence in capsule endoscopy should increase diagnostic accuracy and reading efficiency, and the introduction of motorized spiral enteroscopy into clinical practice could also improve the therapeutic yield. This review focuses on the most recent studies on artificial-intelligence-assisted capsule endoscopy and motorized spiral enteroscopy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...